The TCE 6000 Mass Flow Transmitter is ready for ESTA applications. Outputs available include Analog current output, pulse/frequency output (0.5 to 10,000 Hz), and status output. Choose from either RS485 or HART® interfaces. It works with the TRD 8001 Remote Display.
Display: | back-lit LCD screen, 132 x 32 dot |
Supply Voltage: | via interface |
Programming: | via front keyboard |
Interface to TCE: | RS485 |
EMC: | according to EN 61000-6-4 and 61000-6-2 |
Electrical Connections: | connectors M12, B coded |
Housing Material: | ABS-FR (plastic, flame retardant) |
Protection Class: | IP64 |
Dimensions: | 90 x 120 x 50 mm (h x w x d) |
Weight: | 0.4 kg/0.88 lb |
Wall Mount: | hidden screws |
Temperature: | operation: 32 °F … +140 °F (0 °C … +60 °C ) storage and transport: -4 °F … +176 °F (-20 °C … +80 °C) |
Ex Certification: | ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T4 Gc |
TRICOR® Coriolis Technology Ltd.
When you combine decades of experience with truly unique talents, great things can happen. TRICOR engineers have been intimately involved with the development and evolution of Coriolis flow instrumentation since the beginning. In fact, many of the critical patents for Coriolis technology bear our engineers’ names. The TRICOR Coriolis range of globally-certified flow measurement products are designed and engineered in Germany with support teams in the United States and Switzerland. Our state-of-the-art manufacturing facility in Karlsfeld, Germany is equipped with advanced calibration and test equipment that guarantees world-class performance and the highest-accuracy, delivering flow measurement solutions for the most demanding applications.