Benefits:
- Transmits flow rate, total, density or temperature
- Approvals for use in Hazardous Areas
Wall mounted multi-variable Coriolis flow transmitter that can output flow rate, density, and temperature
Outputs available:- Analog current output (up to 2)
- Pulse/frequency output (0.5 – 10,000 Hz)
- Status output
- RS485
- HART®
- Foundation Fieldbus®
- ATEX
- IECEx
- cCSAus
GENERAL | |
Display: | back-lit LCD screen, 132 x 32 dot |
Supply Voltage: | 24 V DC, ±20 % or 90 … 264 V (version dependent) |
Programming: | via front keyboard or Windows-based TRICOR configurator program (Modbus) |
Interface: | RS485 (Modbus RTU), HART®, Foundation Fieldbus® other options on request |
EMC: | according to EN 61000-6-4 and 61000-6-2 |
Power Consumption: | max. 6 W |
Electrical Connections: | cage clamp terminals |
Housing Material: | aluminum diecast (option: 1.4404/AISI 316L) |
Protection Class: | IP65 (IP66/IP67 on request) |
Weight: | aluminum diecast housing: 3.8 kg/8.3 lb (3 m cable) 1.4404/AISI 316L housing: 6.15 kg/13.56 lb |
Temperature: | ambient: -40 °F … +158 °F (-40 °C … +70 °C) storage and transport: -40 °F … +176 °F (-40 °C … +80 °C) |
ANALOG OUTPUT | |
Current Outputs (2x): | 4 … 20 mA passive, two-wire, isolated |
Resolution: | 14 bit |
Linearity: | ±0.05 % of full scale |
Temperature Drift: | 0.05 % per 10 K |
Load: | < 620 Ω (at 24 V supply) |
Output Value: | programmable: flow, total, density, temperature |
PULSE OUTPUT | |
Frequency Range: | 0.5 – 10,000 Hz |
Output Signal: | active push pull output for flow rate |
STATUS IN- AND OUTPUT | |
Status Output: | push pull programmable (in TOTAL mode: 0.5 – 100 Hz; in FREQUENCY mode: 0.5 – 10,000 Hz) |
Control Input: | programmable |
ANALOG INPUT (OPTION) | |
Input Type: | 4 … 20 mA active for two-wire passive pressure sensor |
Resolution: | 12 bit |
Linearity: | ±0.05 % of full scale |
Temperature Drift: | 0.05 % per 10 K |
Supply Voltage: | > 20 V (at 20 mA sensor current) |
EX CERTIFICATIONS | |
ATEX (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
ATEX (Exn): | Zone 2: II 3G Ex nA IIC T2…T4 Gc |
IECEx (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
cCSAus (Ex1): | Class 1, Division 1: Group A, B, C, D or C, D, T2…T4 |
For Ex1 the electronic is only available in aluminum housing. | |
ATEX + IECEx + cCSAus triple approval (Ex3): | Zone 1: Group IIC or IIB, T2…T4 and Class 1, Division 1: Group A, B, C, D or C, D, T2…T4 |
For Ex3 the electronic is only available remote and in aluminum housing. | |
EAC (TR-CU): | Group IIC or IIB, T2…T4 |
For EAC (TR-CU) the electronic is only available in aluminum housing. |
TRICOR® Coriolis Technology Ltd.
When you combine decades of experience with truly unique talents, great things can happen. TRICOR engineers have been intimately involved with the development and evolution of Coriolis flow instrumentation since the beginning. In fact, many of the critical patents for Coriolis technology bear our engineers’ names. The TRICOR Coriolis range of globally-certified flow measurement products are designed and engineered in Germany with support teams in the United States and Switzerland. Our state-of-the-art manufacturing facility in Karlsfeld, Germany is equipped with advanced calibration and test equipment that guarantees world-class performance and the highest-accuracy, delivering flow measurement solutions for the most demanding applications.