Superior images and temperature measurement on metal and ceramics at lower temperature between 150…800 °C (MC320M, MC320ME) or between 400…1600 °C (MC320MHT, MC320MHTE).
- High performance, cost-effective complete monitoring solution
- Advanced maintenance-free electronics and industrial protective packaging
- Serves the industry’s broadest range of process monitoring applications
- Superior images and temperature measurement for long- and mid-wave applications
- Supports low and high temperature applications
- Optional industrial grade rugged enclosure for harsh environments
- Gigabit Ethernet communication
- Support for IO module, OPC, and Modbus through LumaSpec RT Software
Rolling processes
Technical Data
Performance | |
Temperature Range: | MC320M
Range 1 302 °F to 932 °F (150 °C to 500 °C) Range 2 392 °F to 1472 °F (200 °C to 800 °C) MC320MHT Range 752 °F to 2912 °F (400 °C to 1600 °C) |
Spectral Range: | 3 – 5 μm |
Measurement Accuracy: | ±2 °C or 2% of reading |
Image Update Rate: | 60 Hz (Standard); 9 Hz (E series) |
A/D Resolution: | 16 bit |
Detector: | 320 x 240 Uncooled Focal Plane Array |
Emissivity Correction: | 0.1 to 1.0 |
Transmittance: | 0.1 to 1.0 |
Sensitivity/NETD: | 0.108 °F @ 86 °F
(0.06 °C @ 30 °C) |
Optical Specifications | |
Focus Range: | 30 cm to infinity |
Interface | |
Analog: | TV Output (NTSC or PAL) |
Digital: | Gigabit Ethernet |
Connections: | 4-Pin Power (LEMO-0K), RJ45 Ethernet, 3-pin Trigger (M8), Coaxial (BNC) |
Environmental Specifications | |
Protection Class: | IP54 / NEMA 4 |
Operating Temperature: | 32 to 122 °F (0 °C to 50 °C) (at housing) |
Storage Temperature: | -4 to 158 °F (-20 °C to 70 °C) |
Relative Humidity: | Non condensing conditions |
Weight: | 2.55 lbs. (1 kg) (excludes any protective housing or optional lenses) |
Operating Position: | Any operating position |
Housing: | 6063 T5 Aluminum Alloy. Finish is alodine, clear, MIL-DTL-5541F, RoHS Compliant |
Dimensions: | 3.26 in x 3.20 in x 7.01 in (83 mm x 81.49 mm x 178.28 mm) |
Electrical | |
Power Supply: | 12 – 30V or Power over Ethernet standards |
Power Consumption: | 7W Typical, 13W Max |
Load (analog output): | 75 Ω |
Isolation: | Power supply, communication, and IOs are isolated from each other |
LumaSense
LumaSense systems empower our customers to realize immediate, verifiable, and sustainable savings from efficiency gains and waste reduction that go directly to the bottom line. Typical efficiency gains range from a minimum of 1% and up to 4% – even well beyond – opening the door to billions of dollars of savings in readily preventable expenses for our customers in the Global Energy, Industrial Materials, and Advanced Technologies markets. Systems and sensors span thermal imaging, pyrometry, fiberoptic temperature sensors, non-dispersive infrared and photoacoustic spectroscopy, gas-sensing modules, and a range of purpose-built sensors. These are developed, optimized, and tuned for the specific requirements of resource-intensive global industries and all are integrated into a feature-rich and customizable software solution to optimize the insight these sensors can provide and to allow for integration into controls and automation of processes.