Honeywell Gas Detector Expansion Module 301EM

Acts as a controller for up to four remote refrigerant sensors and detects a wide variety of gases

Honeywell Gas Detector Expansion Module 301EM product thumbnail
Get in Touch
button-arrow-red Back

The Honeywell Analytics Gas Detector Expansion Module 301EM acts as a controller for up to four remote refrigerant sensors and detects a wide variety of gases.

The Honeywell Gas Detector Expansion Module 301EM is easily configured to meet ASHRAE 15, B-52 and International Mechanical Code requirements, the 301EM is commonly used to optimise gas detection in mechanical and chiller rooms.

A full complement of sensors (including toxic, Oxygen, combustible gases and a full line of refrigerant sensors), horns, strobes and remote panels provide added flexibility to suit a variety of gas detection system solutions.

Brochure
Specifications
Manual

• Easy to read LCD display • Auto-diagnostic capabilities • Convenient stand-alone or network operation • Cost-effective answer for installation in hazardous locationsble Operation • Able to operate with up to twenty remote sensors at a time • Various sensors available to simultaneously detect a range of different gases • Robust and reliable RS-485 Modbus communication

ASHRAE No 15-2001 Mechanical Standard and B-52 Code Compliance
The ASHRAE and B-52 security standards have been established to minimise risk and protect the safety of mechanical room personnel and the environment at large. Available in a special configuration, the 301EM mechanical room controller has been carefully designed to meet and even exceed these rigorous standards. The Vulcain 301EM can be configured to offer automatic fan, horn and strobe activation in addition to manual fan activation. Latching relay for manual alarm recognition, silence key for manual horn deactivation, built-in 24 Vdc outputs for horn operation, and 2 breakglass switch accessories for manual alarm activation ensure optimal performance.

Output Adaptability

• Three 24 Vdc alarm outputs and four 4-20 mA outputs

Safety Measures

• Four fully programmable relays
• Three alarm levels with built-in visual indicators and audible alarm

Beneficial Options

• Convenient stand-alone or network operation

General Specification Use

Wall mounted mechanical room controller for use with Honeywell Analytics 301IRFS and S301D2 gas sensors for up to 20 points of detection.

Four (4) onboard relays can be used to activate alarms or deactivate equipment.

Power Requirement 22-27 Vac, 29-38 Vdc, 2A max @ 29Vdc

Size 11 (H) x 8 (W) x 2.7 (D) in. (28 x 20.3 x 7 cm)

Weight 2.25 lbs. (1.02 kg)

Distance Between Controller

and Sensor

301IRFS refrigerant sensors: Up to 200 ft. (60.9 m)

S301D2 toxic/combustible sensors: Up to 500 ft. (160 m)

Visual Indicators Normal Operation Green LED

Alarm Level 1 Red LED

Alarm Level 2 Red LED

Alarm Level 3 Red LED

Signal Tx Blinking amber LED

Failure Indication Yellow LED

Alarm Levels 3 with high and low setpoints

Outputs 4 DPDT relays (alarms and/or fault), buzzer

Three 24 Vdc, 250mA (per output)

Four 4-20mA outputs

Modbus

RFS option: 24 Vdc built-in red strobe

RFSA option: 24 Vdc built-in red strobe & 105 dBA horn

Relay Output Rating 5 A, 30 Vdc or 250 Vac (resistive load)

Gases Detected Gases Detected Detection Range Operating Temperature Operating Humidity Range

301IRFS

R11, R22, R123, R125, R134A,

R404A, R407C, R410A, R507A

0-1,000 ppm 32° to 104°F (0° to 40 °C) 0-95% non-condensing

S301D2

Carbon Monoxide (CO) 0-250 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing

Chlorine (Cl2) 0-15 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing

Nitrogen Dioxide (NO2) 0-10 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing

Hydrogen Sulfide (H2S) 0-50 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing

Sulfur Dioxide (SO2) 0-10 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing

Oxygen (O2) 0-25% -4° to 104°F (-20° to 40°C) 0-95% non-condensing

Combustibles 0-100% LEL -40° to 112°F (-40° to 50°C) 0-95% non-condensing

Ratings and Certification

Alarm Levels CAN/CSA C22.2 No. 61010-1

116662

Conforms to ANSI/UL 61010-1

Honeywell Analytics - Honeywell Gas Detector Expansion Module 301EM
Order #Model #Description
301-EM-CA1Controller, Type 1 Canada
301-EM-CA2Controller, Type 2 Canada
301-EM-US3Controller, Type 3 US
301-EM-RFSA-CA1Controller with horn and strobe, Type 1 Canada
301-EM-RFSA-CA2Controller with horn and strobe, Type 2 Canada
301-EM-RFSA-US3Controller with horn and strobe, Type 3 US
301-EMRPRemote panel
301-EMRP-RFSARemote panel with horn and strobe
301-IRFS-R11R11 refrigerant gas sensor
301-IRFS-R123R123 refrigerant gas sensor
301-IRFS-R125R125 refrigerant gas sensor
301-IRFS-R134AR134a refrigerant gas sensor
301-IRFS-R22R22 refrigerant gas sensor
301-IRFS-R404A
R404a refrigerant gas sensor
301-IRFS-R407CR407c refrigerant gas sensor
301-IRFS-R410AR410a refrigerant gas sensor
301-IRFS-R4310R4310 refrigerant gas sensor
301-IRFS-R507AR507a refrigerant gas sensor
129570-L3S301D2COMBCombustible explosion proof sensor - (GAIN 1.0-1.3 / Methane)
129426-L3S301D2COMBCombustible explosion proof sensor - (GAIN 1.3-1.599 / Hydrogen)
129427-L3S301D2COMBCombustible explosion proof sensor - (GAIN 1.6-1.999 / Propane, Ethanol)
129428-L3S301D2COMBCombustible explosion proof sensor - (GAIN 2.0-2.219 / n-Pentane)
129429-L3S301D2COMBCombustible explosion proof sensor - (GAIN 2.220-2.5 / Toluene)
129430-L3S301D2COMBCombustible explosion proof sensor - (GAIN +2.5 / n-Decane)
129431-L3S301D2COCarbon monoxide (CO) explosion proof sensor
129435-L3S301D2CL2Chlorine (Cl2) explosion proof sensor
129432-L3S301D2NO2Nitrogen dioxide (NO2) explosion proof sensor
129433-L3S301D2H2SHydrogen sulfide (H2S) explosion proof sensor
129436-L3S301D2O2Oxygen (O2) explosion proof sensor
129434-L3S301D2SO2Sulfur dioxide (SO2) explosion proof sensor
M-511071EC-F9-NH3-0/100-N1-EMAmmonia (NH3) monitor, 4-20 mA, Modbus, 0-100 ppm, NEMA 1 encl.
M-511072EC-F9-NH3-0/250-N1-EMAmmonia (NH3) monitor, 4-20 mA, Modbus 0-250 ppm, NEMA 1 encl.
M-511010EC-F9-NH3-0/500-N1-EMAmmonia (NH3) monitor, 4-20 mA, Modbus 0-500 ppm, NEMA 1 encl.
M-508617EMBGBreak glass manual switch option for 301EM
M-700123301EM-20 light stack assembly
M-505352IRFSENSORGUARDMetal guard for 301IRFS sensors
M-505913SEL-2POS-120V2-Position selector switch - 120 Vac
M-505912BP-120V-NO-NCPush button NO/NC - 120 Vac
M-505911BP-120V-LOCKEDPush button NO/NC locked - 120 Vac
HPV5DC8ULHPV5DC8UL12/24 Vdc Power Supply, UL/cUL Listed, 2.5A @ 24Vdc

Honeywell Analytics

For nearly 50 years, Honeywell Analytics has been protecting people who put their lives on the line every day. It takes a special level of drive and dedication to work in hostile environments, and we believe your workers deserve the same kind of commitment from us when it comes to securing their health and safety. Right from the start, our founders were determined to find better ways to design, build and manufacture reliable gas detection solutions. Through advanced technology and pure industry know-how, Honeywell Analytics continues to improve and evolve our products. Today, we’re proud to partner with customers worldwide who share our vision of vigilance and rely on us to help them protect what matters most. From custom-designed solutions to unmatched training and support, Honeywell Analytics is simply the smartest choice when you demand the best in safety.

Sensor controller with auto-diagnostic capabilities – 301EM from Honeywell Analytics

Have any questions?

We'd love to help

Get in touch

Call Us Toll Free Across Canada!

1.888.388.1592

Corporate Headquarters

101-11127 15 Street NE,
Calgary, AB Canada T3K 2M4
1.403.250.1594
edge-footer-top-blue footer-tower
  • LinkedIn
  • YouTube
View all Accreditations
  • COR
  • ISN
  • Avetta
A sillouette of an oil and gas plant.

© 2025 MicroWatt Controls | Website by True Market