The new generation of the Honeywell Analytics commercial gas monitor SQN8x series combines long proven sensing capabilities with state-of-the-art pumping technology to yield a highly reliable sample draw gas detection system.
The SQN8x offers accurate monitoring of the presence of a wide variety of refrigerants or other toxic and explosive gases in a surveillance area of up to 8 different zones. A low maintenance diaphragm pump draws ambient air to the sensor from a maximum distance of 1000 feet. A high performance sequencer synchronizes the mechanics and the electronics so that the levels of detectable gases are properly registered for each of the 8 zones. The unit is fully operational from the box, making for simple, hassle-free installation. The new generation of Honeywell Analytics commercial gas monitor SQN8x provides an excellent, cost-effective, centralized gas detection solution.
Additional Features and Benefits:
Safety Measures
• 3 alarm relays
• Audible alarm
• Early low level warning alarm
• Integrated flow loss surveillance
Reliable
• Wide area of coverage
• 2, 4 or 8 sample points
• Proven sensing technology
• Up to 2 gases
General Specification Use
Sample draw detector that rotates pumping in air samples from up to eight different locations and detects for
possible gas hazards
Size 19 (H) x 13 (W) x 3.7 (D) in. (48 x 33 x 10 cm)
Weight 26.5 lbs. (12 kg)
Power Requirement 24Vac, 0.74A
Relay Output Rating 5A, 30 Vdc or 250 Vac (resistive load)
Audible Alarm 110 dBA at 3 ft. (1 m)
Alarm Levels 3 alarm levels
Number of Sample Points Up to 8, including 1/8 in. polymer tubing
Outputs 3 DPDT relays
(3 alarms level or 2 alarm levels and Fault)
RS-485
Operating Humidity Range 15-90% RH (non-condensing) toxics
0-99% RH (non-condensing) refrigerants
Operating Temperature Range 32° to 100°F (0° to 40°C)
Maximum Sampling Distance 1,000 ft. (305 m)
Visual Indicators Normal Operation Green LED
Alarm Level 1 Red LED
Alarm Level 2 Red LED
Failure indication Yellow LED
Aspirated Zone Green LED
Gases Detected Gas Detected Detection Range Sensitivity Accuracy
301IRFS
Refrigerants R11, R12,
R13B1, R22, R123, R125,
R134a, R227, R245A,
R404A, R407C, R410A,
R507a, R508B
0-1,000 ppm 4 ppm ±40 ppm @ 500 ppm
S301D2
Carbon Monoxide (CO) 0-250 ppm 1 ppm 3%
Nitrogen Dioxide (NO2) 0-10 ppm 0.05 ppm 3%
Combustibles 0-100% LEL 0.5% LEL 3%
Oxygen (O2) 0-25% vol. 0.1% vol. 3%
Ratings and Certifications
Certified to
CSA STD. C22.2 No. 205
116662
Honeywell Analytics - Honeywell Commercial Gas Monitor System SQN8x | ||
---|---|---|
Order # | Model # | Description |
M-508740 | VASQN82-R22 | R22, 0-1000 ppmv |
M-509624 | VASQN82-R11 | R11, 0-1000 ppm |
M-508699 | VASQN82-R123 | R123, 0-1000 ppm |
M-509637 | VASQN82-R125 | R125, 0-1000 ppm |
M-509638 | VASQN82-R134A | R134A, 0-1000 ppm |
M-509641 | VASQN82-R404A | R404A, 0-1000 ppm |
M-509642 | VASQN82-R507 | R507, 0-1000 ppm |
M-509748 | VASQN82-O2 | O2, 0-25% |
M-509760 | VASQN82-CO | CO, 0-250 ppm |
M-509761 | VASQN82-COMB | COMB, 0-100% LEL |
M-509762 | VASQN82-NO2 | NO2, 0-10 ppm |
M-508747 | VASQN82-R22-R123 | R22-R123, 0-1000 ppm |
M-509643 | VASQN82-R11-R123 | R11-R123, 0-1000 ppm |
M-509644 | VASQN82-R11-R125 | R11-R125, 0-1000 ppm |
M-509645 | VASQN82-R11-R134A | R11-R134A, 0-1000 ppm |
M-509657 | VASQN82-R22-R125 | R22-R125, 0-1000 ppm |
M-509648 | VASQN82-R11-R404A | R11-R404A, 0-1000 ppm |
M-509649 | VASQN82-R11-R507 | R11-R507, 0-1000 ppm |
M-509657 | VASQN82-R22-R125 | R22-R125, 0-1000 ppm |
M-509658 | VASQN82-R22-R134A | R22-R134A, 0-1000 ppm |
M-509661 | VASQN82-R22-R404A | R22-R404A, 0-1000 ppm |
M-509662 | VASQN82-R22-R507 | R22-R507, 0-1000 ppm |
M-509657 | VASQN82-R22-R125 | R22-R125, 0-1000 ppm |
M-509789 | VASQN82-CO-COMB | CO-COMB, 0-250 ppm, 0-100% LEL |
M-509790 | VASQN82-CO-NO2 | CO-NO2, 0-250 ppm, 0-10 ppm |
M-503798 | VASQN84-NO2 | NO2, 0-10 ppm |
M-508722 | VASQN84-R123 | R123, 0-1000 ppm |
M-508741 | VASQN84-R22 | R22, 0-1000 ppm |
M-509663 | VASQN84-R11 | R11, 0-1000 ppm |
M-509664 | VASQN84-R125 | R125, 0-1000 ppm |
M-509665 | VASQN84-R134A | R134A, 0-1000 ppm |
M-509668 | VASQN84-R404A | R404A, 0-1000 ppm |
M-509669 | VASQN84-R507 | R507, 0-1000 ppm |
M-509763 | VASQN84-CO | CO, 0-250 ppm |
M-509764 | VASQN84-COMB | COMB, 0-100% LEL |
M-509766 | VASQN84-O2 | O2, 0-25% |
M-503806 | VASQN84-R11-R22 | R11-R22, 0-1000 ppm |
M-508748 | VASQN84-R22-R123 | R22-R123, 0-1000 ppm |
M-509324 | VASQN84-R11-R123 | R11-R123, 0-1000 ppm |
M-509670 | VASQN84-R11-R125 | R11-R125, 0-1000 ppm |
M-509671 | VASQN84-R11-R134A | R11-R134A, 0-1000 ppm |
M-509674 | VASQN84-R11-R404A | R11-R404A, 0-1000 ppm |
M-509675 | VASQN84-R11-R507 | R11-R507, 0-1000 ppm |
M-509683 | VASQN84-R22-R125 | R22-R125, 0-1000 ppm |
M-509684 | VASQN84-R22-R134A | R22-R134A, 0-1000 ppm |
M-509687 | VASQN84-R22-R404A | R22-R404A, 0-1000 ppm |
M-509688 | VASQN84-R22-R507 | R22-R507, 0-1000 ppm |
M-510250 | VASQN84-R134A-COMB | R134A-COMB, 0-1000 ppm, 100% LEL |
M-510459 | VASQN84-R123-R134A | R123-R134A, 0-1000 ppm |
M-503929 | VASQN88-NO2 | NO2, 0-10 ppm |
M-508723 | VASQN88-R123 | R123, 0-1000 ppm |
M-508742 | VASQN88-R22 | R22, 0-1000 ppm |
M-509689 | VASQN88-R11 | R11, 0-1000 ppm |
M-509691 | VASQN88-R125 | R125, 0-1000 ppm |
M-509692 | VASQN88-R134A | R134A, 0-1000 ppm |
M-509695 | VASQN88-R404A | R404A, 0-1000 ppm |
M-509696 | VASQN88-R507 | R507, 0-1000 ppm |
M-509767 | VASQN88-CO | CO, 0-250 ppm |
M-509768 | VASQN88II-COMB | COMB, 0-100% LEL |
M-509770 | VASQN88-O2 | O2, 0-25% |
CVIP3751 | VASQN88-R410A | R410A, 0-1000 ppm |
M-503937 | VASQN88-R11-R22 | R11-R22, 0-1000 ppm |
M-508749 | VASQN88-R22-R123 | R22-R12, 0-1000 ppm |
M-509480 | VASQN88-R22-R134A | R22-R134A, 0-1000 ppm |
M-509619 | VASQN88-R123-R134A | R123-R134A, 0-1000 ppm |
M-509697 | VASQN88-R11-R123 | R11-R123, 0-1000 ppm |
M-509698 | VASQN88-R11-R125 | R11-R125, 0-1000 ppm |
M-509699 | VASQN88-R11-R134A | R11-R134A, 0-1000 ppm |
M-509702 | VASQN88-R11-R404A | R11-R404A, 0-1000 ppm |
M-509703 | VASQN88-R11-R507 | R11-R507, 0-1000 ppm |
M-509711 | VASQN88-R22-R125 | R22-R125, 0-1000 ppm |
M-509714 | VASQN88-R22-R404A | R22-R404A, 0-1000 ppm |
M-509715 | VASQN88-R22-R507 | R22-R507, 0-1000 ppm |
M-700202 | VASQN88-R4310-O2 | R4310-O2, 0-1000 ppm, 0-25% |
M-509802 | VASQN88-CO-NO2 | CO-NO2, 0-250 ppm, 0-10 ppm |
M-509805 | VASQN88-COMB-O2 | COMB-O2, 0-100% LEL, 0-25% |
0235-0295 | 8XTL5 | 200 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) |
0235-0296 | 8XTL9 | 400 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) |
0235-0297 | 8XTL14 | 800 ft. sampling tube (0.17 in. I.D., 0.25 in. O.D.) |
M-510806 | Vacuum filter, 50 micron | |
M-504183 | Sampling point with filter |
Honeywell Analytics
For nearly 50 years, Honeywell Analytics has been protecting people who put their lives on the line every day. It takes a special level of drive and dedication to work in hostile environments, and we believe your workers deserve the same kind of commitment from us when it comes to securing their health and safety. Right from the start, our founders were determined to find better ways to design, build and manufacture reliable gas detection solutions. Through advanced technology and pure industry know-how, Honeywell Analytics continues to improve and evolve our products. Today, we’re proud to partner with customers worldwide who share our vision of vigilance and rely on us to help them protect what matters most. From custom-designed solutions to unmatched training and support, Honeywell Analytics is simply the smartest choice when you demand the best in safety.